Kajian Kerusakan Struktur Gedung Fakultas Kesehatan Masyarakat Unand Akibat Kebakaran Tanggal 8 Mei 2025

Authors

  • Jeply Murdiaman Guci Universitas Andalas
  • Jafril Tanjung Universitas Andalas
  • Taufik Alhakim Iskandar Departemen Teknik Sipil, Fakultas Teknik, Universitas Andalas, Padang, Sumatera Barat

DOI:

https://doi.org/10.25077/jbkd.4.1.33-44.2026

Keywords:

kebakaran gedung, evaluasi struktur, beton bertulang, pengujian non-destruktif, kelaikan bangunan.

Abstract

The fire that occurred at the Faculty of Public Health (FKM) Building of Universitas Andalas on May 8, 2025 raised concerns regarding the serviceability and structural safety of the building before it could be reused as an educational facility. Post-fire building conditions may experience degradation of material quality and damage to both structural and non-structural elements; therefore, a comprehensive technical evaluation in accordance with applicable building regulations is required. This study aims to evaluate the condition and serviceability of the main structural components of the FKM building after the fire and to formulate technical repair recommendations to ensure the safety and security of building users.

The research method was carried out through field observations and non-destructive testing of reinforced concrete structural elements, including visual inspection, measurement of structural element dimensions, evaluation of verticality, concrete hammer testing, and identification of cracks and deformations. In addition, inspections were conducted on non-structural elements and supporting building materials affected by the fire, such as roof structures, ceilings, partitions, and canopy elements, to identify the level of damage and the need for repair or replacement.

The evaluation results indicate that the main structural elements, namely columns, beams, and floor slabs, still meet technical requirements and structural serviceability criteria, with concrete quality relatively consistent with the original design, namely K-250 or equivalent to a concrete compressive strength (fc’) of 20.75 MPa. No significant damage was found in the main structural elements that could compromise the building’s integrity. However, several non-structural elements and roof structures—particularly steel purlins, ceilings, partitions, and wooden components of the canopy roof (drop-off)—sustained damage due to heat and fire exposure and therefore require repair and replacement.

The conclusion of this study states that the FKM Universitas Andalas building is generally still suitable for use, provided that comprehensive repairs are carried out on damaged components, strengthening of affected roof structural elements is implemented, and the fire protection system is improved. The technical recommendations produced are expected to serve as a reference in the building rehabilitation process so that the facility can be safely reused in accordance with building safety standards.

Downloads

Download data is not yet available.

References

Asteris, P. G., & Mokos, V. G. (2020). Concrete compressive strength using artificial neural networks. Neural Computing and Applications, 32(15), 11807–11826.

Chiang, C.-H., & Tsai, C.-L. (2003). Time-temperature analysis of bond strength of a rebar after fire exposure. Cement and Concrete Research, 33(10), 1651–1654.

Chilibon, I. (2015). Non-destructive evaluation methods of materials and structures. Defect and Diffusion Forum, 364, 122–131.

Gupta, A. K. (2009). Non destructive evaluation of new concrete construction. Journal of Structural Engineering (Madras), 36(1), 54–58.

Hutchinson, T. C., & Chen, Z. (2010). Image-based framework for concrete surface crack monitoring and quantification. Advances in Civil Engineering, 2010.

Iwankiw, N. (2007). Structural fire resistant design basics for concrete, masonry, and wood. Practice Periodical on Structural Design and Construction, 12(1), 3–8.

Murdiaman Guci, J., Zulhendra, R., Putri Yastari, F., & Putri Elza, S. (2025). Studi Komparatif Efisiensi Struktur Mall 7 Lantai pada Tanah SE dan SD terhadap Beban Gempa di Sumatera Barat. In Jurnal Media Konstruksi (Vol. 10, Issue 2).

PP Nomor 16 Tahun 2021. (2021).

Rydval, M., Kolisko, J., & Simunek, I. (2017). Lightweight concrete with different content of PP fibers exposed to high temperature. Key Engineering Materials, 722 KEM, 33–37.

Tabatabaeian, A., Fotouhi, S., & Fotouhi, M. (2024). Visual inspection of impact damage in composite materials. In Non-destructive Testing of Impact Damage in Fiber-reinforced Polymer Composites: Fundamentals and Applications (pp. 43–67).

Vijay, P. V, Tulasi Gadde, K., & Gangarao, H. V. S. (2019). Structural Evaluation and Rehabilitation of Century-Old Masonry and Timber Buildings. Journal of Architectural Engineering, 25(2).

Published

31-03-2026

How to Cite

Guci, J. M., Jafril Tanjung, & Iskandar, T. A. (2026). Kajian Kerusakan Struktur Gedung Fakultas Kesehatan Masyarakat Unand Akibat Kebakaran Tanggal 8 Mei 2025. Jurnal Bangunan, Konstruksi & Desain, 4(1), 33–44. https://doi.org/10.25077/jbkd.4.1.33-44.2026

Issue

Section

Articles